Cathodic Protection

Cathodic Protection Companies in Wisconsin

Wisconsin cathodic protection testing under ATCP 93, plus anode repair, impressed current surveys and corrosion monitoring for tank sites in Milwaukee, Madison, Green Bay and Appleton.

What to Know About Cathodic Protection in Wisconsin

Cathodic protection in Wisconsin runs on stricter rules than the federal minimum. DATCP's Bureau of Weights and Measures regulates tank systems here, and a CP tester needs a DATCP Cathodic Protection Tester certification and must work for a registered Tank Specialty Firm, per the DATCP technician rules. The work itself keeps buried steel from rusting through by feeding it a small protective current from sacrificial anodes or a powered rectifier, then measuring whether that current is enough. Designing or installing a system takes a separate DATCP Corrosion Expert certification, though ATCP 93.240(21) excepts department-accepted factory-supplied systems such as sti-P3. On a Milwaukee or Green Bay station sale, the buyer's Phase I environmental review is often where missing test records first come to light.

Wisconsin's annual cycle multiplies the work. Because ATCP 93.520 requires CP testing at least once a year instead of every three years, a protected tank at a Milwaukee, Racine or Kenosha station gets about three tester visits for every one the federal minimum would require. Freeze-thaw winters complicate a yearly schedule, since a test station under frozen ground in the Northwoods may not open until spring. Owners in Madison or Appleton can use the Wisconsin UST contractor directory and ask each firm whether it employs a DATCP-certified tester.

No two Wisconsin CP bills look alike, because ATCP 93.520 ties the number of readings to each site's layout. Any piping run longer than 50 feet gets an extra reading every 25 feet, so a long fleet-yard line in Green Bay takes far more meter time than a short run at a corner station. Impressed current sites add instant-off potentials to the annual test, and a paved-over test station can mean coring concrete. Fixing a failed survey is the largest variable. A release found during that work has no PECFA path, since PECFA closed to new claims as of June 30, 2020. Fox Valley owners can request a Wisconsin CP quote and give the total piping length, since it drives the reading count.

On a typical Appleton or Green Bay visit, the tester opens each test station, sets a reference electrode in moist soil and reads structure-to-soil potential on every tank and piping run. An impressed current site adds a rectifier check, and contractors must notify local utilities when they adjust one under ATCP 93.520. A single-tank sacrificial anode site is often one short visit, while a multi-tank station with long piping can fill a day. Before hiring, ask to see the tester's DATCP credential and, if new anodes will go into petroleum-stained soil, whether the crew holds OSHA hazardous waste worker training. Have last year's readings on hand beforehand, so the tester can compare each station and catch a weakening one before it fails.

Wisconsin contractors for cathodic protection

See all Wisconsin contractors

Frequently Asked Questions

Who is allowed to test CP on a Wisconsin UST?

The tester must hold DATCP tester certification and work for a registered Tank Specialty Firm, per the DATCP technician page. DATCP accepts NACE CP 1 tester, CP 2 technician and CP 3 technologist credentials toward that certification, and the NACE CP credential levels page explains each tier. One carve-out applies: under ATCP 93.520, tanks designated sti-P3 may also be tested by a person holding Steel Tank Institute certification. Under ATCP 93.240(21), the tester and the tester's employer must have no personal or monetary interest in the facility. That rules out a Kenosha station's own maintenance worker, even a trained one.

What drives the price of CP work in Wisconsin?

Tank count and piping length set most of the bill. Long piping runs at a Milwaukee station add readings, and impressed current sites add instant-off potentials. The widest swing follows a failed CP survey. If the rectifier and its wiring still test sound while the anodes are spent, replacing the anodes alone may fix the problem without a whole new system. Ask for the survey, any repair and the six-month retest required by ATCP 93.520 as separate line items.

How often does Wisconsin require a CP test?

ATCP 93.520 calls for a test at least once a year, plus one within six months of installation or repair. The federal rule in 40 CFR 280.31 asks for CP testing every three years. For sti-P3 tanks with factory anodes and a test station, the cycle is every three years until ten years old, then annually. Impressed current systems also get corrosion monitoring from the site operator at least every sixty days. Tightness testing is a separate DATCP credential, covered on the Wisconsin tightness and leak detection testing page.

What happens after a failed anode reading under ATCP 93?

Under ATCP 93.520, a sacrificial anode system must hold at least negative 850 millivolts. After a failed reading, the owner has ninety days to find and repair the cause or empty the tank until it is fixed, unless DATCP or its authorized agent agrees to follow-up testing. Spent anodes, a broken test wire and stray current from a nearby impressed current system are common causes. A retest follows within six months. Northwoods sites should plan around frozen ground, which can eat weeks out of that window.

What goes on Wisconsin form TR-WM-141?

TR-WM-141 is DATCP's UST Corrosion Protection Test/Survey Report, where the results of each CP test are summarized. It stays on site under ATCP 93.520. The summary should reflect the extra piping readings every 25 feet and, on impressed current systems, the instant-off potentials. A Green Bay buyer can compare several years of reports to spot anodes wearing down. An instant-off number removes the error from current flowing through the soil; how anode and rectifier systems work covers the hardware.

For Wisconsin UST regulations, visit the Wisconsin Department of Agriculture, Trade and Consumer Protection. Federal requirements are available from the EPA UST Program.