Skip to main content
Cathodic Protection

Cathodic Protection Companies in Arizona

Arizona CP testing, sacrificial anode repair and impressed current service for steel USTs, with cathodic protection contractors in Phoenix, Tucson, Mesa and Flagstaff.

What to Know About Cathodic Protection in Arizona

Arizona law makes cathodic protection a tank service that needs ADEQ certification. Under A.R.S. 49-1082, nobody may perform CP work on a UST system unless ADEQ has certified them or a certified person supervises them on site. The rule follows the person, not the job site, so a general contractor building a Sonoran Desert fuel stop still needs a certified CP specialist, or one supervising on site, before any anode goes in. On a Phoenix or Tucson property deal, the environmental due diligence report is a good point to ask which ADEQ-certified person signed the last CP test.

Under A.R.S. 49-1009, a new Arizona UST must be cathodically protected, built of noncorrosive material, steel clad with a noncorrosive material, or designed in a manner that prevents a release. Steel systems therefore carry the CP workload, from older Phoenix, Mesa and Chandler stations to fleet yards around Tucson. The same statute also requires a new tank to meet the federal secondary containment standard in 40 CFR 280.20 as in effect on January 1, 2020. The noncorrosive route in 49-1009 does not end CP work, because metal piping or flex connectors on a fiberglass system may still need protection. Flagstaff and the Verde Valley add mountain travel time for crews based in the Phoenix metro. Owners can compare UST contractors across Arizona and ask each firm for the name and ADEQ certificate of the person who will do the CP work.

Every Arizona CP quote should name the ADEQ-certified individual who will do or supervise the work on site, as A.R.S. 49-1082 requires. Tank and piping counts, the number of test stations and any paving cuts set the rest of the price. Repair work is billed on top. Separately, A.R.S. 49-1052 lets eligible owners elect a baseline assessment of a UST property through January 1, 2033 and request money for its costs. Owners can ask for a CP survey quote and attach photos of the test station lids, so the tester can plan around caliche or paving before the visit.

Readings start at the test stations. The tester takes structure-to-soil potential at each one and switches any rectifier off briefly for instant-off values. Digging a new anode bed at an older Tucson station can mean working near contaminated soil, so confirm the crew also meets HAZWOPER course requirements. ADEQ's certification program under A.R.S. 49-1082 checks a provider's knowledge, skills and work history, so ask the tester how long they have held the CP certification.

Arizona contractors for cathodic protection

See all Arizona contractors

Frequently Asked Questions

Does Arizona require certification for CP work on a UST?

Yes. Under A.R.S. 49-1081, cathodic protection is a defined tank service, alongside installation, tightness testing, closure and interior lining. A.R.S. 49-1082 then requires ADEQ certification for anyone doing that work, or on-site supervision by a certified person. The federal rule separately asks for a tester trained to read stray current and soil resistivity as well as tank potentials and isolation. Phoenix and Tucson owners should see the ADEQ certificate and the tester's training record before CP testing starts.

Why do CP quotes differ between Arizona sites?

A quote that sends an uncertified helper alone to read the stations falls short of Arizona's on-site supervision rule, so price it with the certified person on site. A Scottsdale station with two tanks and four test stations takes far less time than a Tucson fleet yard with long piping runs under fresh paving. Impressed current systems add rectifier readings and interruption work that sacrificial anode systems skip. When an older system still has a working rectifier and intact wiring while most anodes are spent, anode replacement can beat a full new system.

How long does a CP survey take at a Phoenix fuel site?

A Phoenix station with a sacrificial anode system usually takes a few hours on site. A Tucson fleet yard running impressed current through several rectifiers takes longer, since each unit needs on and instant-off readings, the rectifier side of the work outlined in CP system basics. In dry Sonoran Desert soil, testers often wet the ground under the reference electrode so the meter settles on a stable number. Readings after a summer monsoon storm can differ from bone-dry readings, so a sound report notes site conditions.

How does A.R.S. 49-1082 supervision work on an Arizona CP crew?

A.R.S. 49-1081 defines supervision as immediate, on-site control and direction by the ADEQ-certified person. Phone supervision does not count. A certified tester directing a helper from a Tempe office while the helper reads test stations in Mesa falls outside that definition. Under A.R.S. 49-1082, the supervisor answers for everyone working under them, and ADEQ may suspend or revoke certification for incompetence, negligence or fraud. Put the certified person's name in the contract and confirm they stay on site for the whole visit.

What should an Arizona owner expect at a CP retest?

Under 40 CFR 280.31 and 40 CFR 280.33, the federal schedule puts the first check within six months of installation, repeats it at least every three years, and adds a retest within six months of a repair. Flagstaff and other high-country sites are easier to retest before winter freezes the ground around the reference electrode. Expect the tester to compare the new CP survey with your last two reports. Tightness testing is a separate service under A.R.S. 49-1081, covered under Arizona tank inspection services.

For Arizona UST regulations, visit the Arizona Department of Environmental Quality. Federal requirements are available from the EPA UST Program.

Request a Free Quote
Free Quotes